Detailed Technical USER MANUAL FOR: 3.5”-SBC MSB900/L Nordstrasse 11/F CH- 4542 Luterbach Tel.: ++41 (0)32 681 58 00 Fax: ++41 (0)32 681
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 10 RoHS is often referred to as the "lead-free" directive but it restricts the
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 11 1.12. Swiss Quality 100% Made in Switzerland DIGITAL-LOGIC is a member of "
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 12 2. OVERVIEW 2.1. Standard Features of the MSB900/L The MICROSPACE 3.5”-SBC is a mini
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 13 2.3. MSB900 Block Diagram
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 14 2.4. MSB900/MSB900L specifications CPU Specification CPU GEODE LX900 CPU Core Suppl
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 15 Mass Storage Specification FD Floppy disk interface not supported HD E-IDE interf
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 16 Operating Environment Specification Relative humidity 5-90%, non-condensing Vibrati
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 17 2.7. Dimensions & Diagrams 2.7.1. MSB900/L Board / Version Unit: Tolerance:
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 18
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 19
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 2 For internal use only: File: MSB900_Detailed_V1.0 Path: R:\HANDBUCH\MSB\MSB900\MS
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 20
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 21 2.7.2. MSB800CON Part Nr 802205 Board / Version Unit: Tolerance: Date / Author MS
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 22 2.8. MSB900/L Incompatibilities to a standard PC/AT None. 2.9. Related Applicatio
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 23 2.11. Battery-Lifetime Battery specs: Lowest temp. -40°C Nominal temp. +20°C Hig
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 24 4. BIOS HISTORY This BIOS history is for the MSB900/L. This BIOS history is not for t
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 25 5. DETAILED SYSTEM DESCRIPTION This system configuration is based on the ISA architec
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 26 5.3. CPU, Boards and RAMs 5.3.1. CPUs of this MICROSPACE Product Processor: Type:
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 27 5.4.3. Serial Ports COM1-COM2 The serial channels are fully compatible with 16C550 UA
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 28 5.6. Timers and Counters 5.6.1. Programmable Timers An 8253 compatible timer/counter
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 29 5.6.4.1. Standard BIOS ROM Device: FWH Map: E0000 - FFFFFh Core BIOS 128k C0000 -
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 3 Table of Contents 1. Preface...
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 30 CMOS Map Location Description 00h Time of day (seconds) specified in BCD 01h Alarm
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 31 CMOS Map continued... Location Description 0Eh CMOS Location for Bad CMOS and Check
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 32 CMOS Map continued... Location Description 15h Base Memory Size (in kB) - Low Byte
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 33 CMOS Map continued... Location Description 22h Byte 3 Bits 7-6 = Reserved Bits 5-
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 34 CMOS Map continued... Location Description 33h Base Memory Installed Bit 7 = Flag
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 35 5.8.1. EEPROM Memory for Setup The EEPROM is used for setup and configuration data,
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 36 5.9.2. System I/O map The following table details the legacy I/O range for 000h throu
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 37 I/O Map Continued… I/O Addr. Function Size R/W Comment If KEL Memory Offset 100h
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 38 I/O Map Continued… I/O Addr. Function Size R/W Comment 0CCh Master DMA Address -
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 39 I/O Map Continued… I/O Addr. Function Size R/W Comment 3F1h Floppy Status R B 8
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 4 5.6.3. Watchdog...
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 40 6. VGA 6.1. VGA/LCD Controller of the Geode LX900 • Highly integrated flat panel an
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 41 7. VIDEO INPUT The MSB900 contains a low-cost video input port. It consist of LX900’s
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 42 Top view of the MSB900/L
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 43 Bottom view of the MSB900/L
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 44 X1 Power Supply Pin Signal 1 (Shield) Power supply 8-30V 2 NC 3 Power supply GND
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 45 X15 Operator Panel / Flat Panel (bottom side) X15 is intended to be used internally t
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 46 X15 Reverse Pin Configuration MSB900 LVDS X15 (on component side) Attention! When X15
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 47 X31 Keyboard PS/2 and Mouse Utility Connector Connector and Adapter Mini- DIN PS/2
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 48 X39 Serial Port COM2 Header onboard D-SUB connector Signal Pin 1 Pin 1 DCD Pin 2
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 49 X52 USB UDOC (not assembled) Pin Signal Pin Signal 1 VCC 6 NC 2 NC 7 GND 3 US
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 5 1. PREFACE The information contained in this manual has been carefully checked
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 50 X61 Serial Port COM1, Parallel Port LPT1 Header onboard D-SUB connector Signal Pin
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 51 X101 PCI-104 BUS Interface Pin A B C D 1 GND/5.0V KEY2 Reserved +5 AD00 2 VI
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 52 X230 JTAG-Port Pin Signal Pin Signal 1 TCK 2 TMS 3 TDI 4 TDO X301 VGA Mon
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 53 9. JUMPER LOCATIONS ON THE BOARD The following figure shows the location of all jumpe
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 54
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 55 10. CABLE INTERFACES 10.1. The Hard Disk Cable 44pin IDT Terminal for Dual Row (2.00m
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 56 10.2. The COM1/LPT Serial Interface Cable Terminal for dual row 2mm grid and 1mm flat
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 57 10.3. The COM2 Serial Interface Cable DT terminal for dual row 0.1" (2.54mm grid
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 58 11. THERMAL SPECIFICATIONS 11.1. Thermal Analysis for Case Integration The MSB900/L
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 59 12. ASSEMBLY VIEWS 12.1. MSB900/L
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 6 1.5. Recycling Information All components within this product fulfill the requirement
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 60
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 61 12.2. Mechanical Dimensions MSB900 Version Unit: mm (millimeter) Tolerance: +/
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 62 13. PXE-BOOT AND PXE-SETUP IN THE BIOS PXE Protocol PXE is defined on a foundation of
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 63 BIOS-Setup Screen with the LAN-BOOT (PXE) DISABLE / ENABLE menu: After ENABLING the
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 64 14. PXE-LICENSE ORDER The PXE-Function must be licensed before it can be enabled. To o
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 65 15. INDEX 1 10/100 BASE-T Interface 47 A Addressing PCI Devices 23 Application Notes
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 66 RoHS Commitment 9 ROM-BIOS 28 RTC 28 S Safety Precautions 9 Schematics 59 Serial
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 7 1.8. Explanation of Symbols CE Conformity This symbol indicates that the product descr
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 8 1.9. Applicable Documents and Standards The following publications are used in conjunc
DIGITAL-LOGIC AG MSB900/L Detailed Technical Manual V1.0 9 Smart Battery Data Specification Revision 1.1, December 11, 1998. www.sbs-forum.org
Comments to this Manuals