Compaq 2000fc Specifications Page 66

  • Download
  • Add to my manuals
  • Print
  • Page
    / 94
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 65
3. Move the optical drive connector board (2) to the right, and then lift it up to disconnect it from the
system board.
Reverse this procedure to install the optical drive connector board.
4. Remove the three Phillips 3.0 x 2.0 screws (1) that secure the system board to the computer.
5. Lift the system board (2) from the right edge and pull it away from the base enclosure at an angle.
For AMD computer models, see the following image.
When replacing the system board, be sure that the following components are removed from the
defective system board and installed on the replacement system board:
Fan/heat sink assembly (see
Fan/heat sink assembly on page 60)
58 Chapter 4 Removal and replacement procedures