Compaq External RAID Controller & Subsystem User Manual Page 96

  • Download
  • Add to my manuals
  • Print
  • Page
    / 347
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 95
Front Panel Operation
5-28
Channel information will be displayed.
Press ENT on the drive channel you
wish the ID changed.
Press ▼ or ▲ to select “Set SCSI
Channel Pri. Ctlr ID..”, then press
ENT.
Press ▼ or ▲ to select a new ID, then
press ENT for two seconds to confirm.
Setting a SCSI Channel’s Secondary ID - Drive Channel
Press ENT for two seconds to enter the
Main Menu. Press ▼ or ▲ to select
"View and Edit SCSI Channels," then
press ENT.
Channel information will be displayed.
Press ENT on the drive channel you
wish the ID changed.
Press ▼ or ▲ to select “Set SCSI
Channel Sec. Ctlr ID..”, then press
ENT.
Press ▼ or ▲ to select a new ID, then
press ENT for two seconds to confirm.
Setting Channel Bus Terminator
Press ENT for two seconds to enter the
Main Menu. Press ▼ or ▲ to select
"View and Edit SCSI Channels," then
press ENT.
Channel information will be displayed.
Press ▼ or ▲ to select a channel. Press
ENT on a channel you wish the
terminator mode changed.
Press ▼ or ▲ to select “Set SCSI
Channel Terminator,” then press ENT.
View and Edit
SCSI Channels ↕
View and Edit
SCSI Channels ↕
CH1=Drive PID=7
SID=NA SXF=80.0M
CH1=Drive PID=7
SID=NA SXF=20.0M
CH0=Host PID=0
SID=NA SXF=20.0M
Set SCSI Channel
Pri. Ctlr ID ..
Set SCSI Channel
Sec. Ctlr ID ..
Set SCSI Channel
Terminator ..
Set Pri. Ctlr
ID= 7 to ID: 8 ?
Set Sec. Ctlr
ID=NA to ID: 9 ?
Page view 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 346 347

Comments to this Manuals