Compaq HSG80 - StorageWorks RAID Array Controller Specifications Page 73

  • Download
  • Add to my manuals
  • Print
  • Page
    / 396
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 72
3–11
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
Figure 3–6 Controller Port ID and Unit Numbers in Transparent Failover Mode
Assigning Unit Numbers in Multiple-Bus
Failover Mode
In multiple-bus failover mode, the range of assignable units that are accessible from
any port on the subsystem is 0–199. Hosts obtain units by reserving the unit for sole
access. This process is performed on a first-available basis or by assigning host
access. Figure 3–7 illustrates the controller port ID and unit numbers in multiple-bus
failover mode.
Controller A
Port 1 (Active)
Units 0-99
Port 2 (Standby)
Units 100-199
Controller B
Port 1 (Standby)
Units 0-99
Port 2 (Active)
Units 100-199
CXO6187B
Page view 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 395 396

Comments to this Manuals

No comments