Compaq 1200 User's Guide Page 73

  • Download
  • Add to my manuals
  • Print
  • Page
    / 256
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 72
Operation 3-39
The update command updates the device specified or all devices.
For each device, you are asked to confirm that you want to update the
firmware. The default is no. Once the update begins, do not abort the
operation. Doing so will corrupt the firmware on the module.
The lfu command restarts the utility so that console firmware can be updated.
(Another method is shown in Example 3–15, where the user specifies the file
AS1200FW and is prompted to insert the second diskette.)
The default update file, AS1200CP, is selected. The console firmware can now
be updated, using the same procedure as for the I/O firmware.
The exit command returns you to the console from which you entered LFU
(either SRM or AlphaBIOS).
Example 3–15 Selecting AS1200FW to Update Firmware from the
Internal Floppy Disk
P00>>> lfu
***** Loadable Firmware Update Utility *****
Select firmware load device (cda0, dva0, ewa0), or
Press <return> to bypass loading and proceed to LFU: dva0
Please enter the name of the firmware files list, or
Press <return> to use the default filename [AS1200IO,(AS1200CP)]: as1200fw
Copying AS1200FW from DVA0 .
Copying TCREADME from DVA0 .
Copying TCSRMROM from DVA0 ..........................
Copying TCARCROM from DVA0 ...............
Copying CIPCA214 from DVA0
Please insert next floppy containing the firmware,
Press <return> when ready. Or type DONE to abort.
Copying CIPCA214 from DVA0 .
Copying DFPAA246 from DVA0 ...
Copying KZPSAA10 from DVA0 ...
.
.
.
Page view 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 255 256

Comments to this Manuals

No comments