3-26 Compaq ProLiant 8500 Server Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
*1788-Slot X Drive
Array Reports
Incorrect Drive
Replacement. The
following SCSI
drive(s) should have
been replaced: SCSI
Port Y: SCSI ID Z
The following SCSI
drive(s) were
incorrectly replaced:
SCSI Port Y:
SCSI ID Z.
Select F1 to continue
drive array will
remain disabled.
Select F2 to reset
configuration all
data will be lost.
None Drives are not installed in their
original positions, so the drives
have been disabled.
1. Reinstall the drives
correctly as indicated.
2. Press F1 to restart the
computer with the drive
array disabled.
-Or-
Press F2 to use the drives
as configured and lose all
the data on them.
* The 1788 error message can also be displayed inadvertently due to a bad power cable connection to the drive, noise
on the data cable, or a defective SCSI cable. If this message was due to a bad power cable connection, but not incorrect
drive replacement, repair the connection and press F2. If the message is not eliminated by pressing F2, run Array
Diagnostic Utility to resolve.
-Or-
If this message was not due to a bad power cable connection and no drive replacement took place, this could indicate
noise on the data cable. Check cable for proper routing.
-Or-
If this message is due to a defective SCSI cable, replace the cable.
continued