Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1751-Fixed Disk 1
failed Identify
command
None
Fixed disk drive error detected. Run the server setup utility and
correct.
1752-Slot X Drive
Array This
controller is not
supported in systems
with more than 3 GB
of memory. The array
controller will be
disabled. (RESUME =
F1 KEY)
None The array controller cannot
access physical system memory
above the 3 GB address range.
Remove the array controller and
replace with a version that will
address memory in the required
range.
1760-Fixed Disk 0
does not support
Block Mode
None
Fixed disk drive error detected. Run the server setup utility and
correct.
1761-Fixed Disk 1
does not support
Block Mode
None
Fixed disk drive error detected. Run the server setup utility and
correct.
1764-Slot X Drive Array - Capacity Expansion Process is temporarily disabled
(followed by one of the following):
Expansion will resume when Array Accelerator has been reattached.
Expansion will resume when Array Accelerator has been replaced.
Expansion will resume when Array Accelerator RAM allocation is successful.
Expansion will resume when Array Accelerator battery reaches full charge.
Expansion will resume when automatic data recovery has been completed.
Reattach or replace array
accelerator. Wait until the array
accelerator batteries have
charged or for Automatic Data
Recovery to complete, as
indicated.
1765-Slot X Drive Array Option ROM Appears to Conflict with an ISA Card. ISA
cards with 16-bit memory cannot be configured in memory range C0000 to DFFFF
along with the SMART-2/E 8-bit Option ROM due to EISA bus limitations.
Please remove or reconfigure the ISA card.
Remove or reconfigure
conflicting ISA cards. Disable
shared memory on any ISA
network cards that may be
installed.
1766-Slot X Drive Array requires System ROM Upgrade. Run Systems ROMPaq
Utility.
Run the latest Systems ROMPaq
Utility to upgrade the system
ROMs.
1767-Slot X Drive Array Option ROM is not programmed correctly or may conflict
with the Memory Address Range of an ISA Card. Check the Memory Address
Configuration of installed ISA Card(s) or run Options ROMPaq Utility to attempt
SMART-2/E Option ROM Reprogramming.
Remove or reconfigure
conflicting ISA cards, especially
any cards that are not
recognized by the System
Configuration Utility. Try
reprogramming the ROM on the
SMART-2/E controller using the
latest Options ROMPaq
(version 2.29 or higher).
1768-Slot X Drive
Array - Resuming
logical drive
expansion process.
None SMART-2 Controller error No action required. Message
appears whenever a controller
reset or power cycle occurs
while array expansion is in
progress.
continued