Diagnostic Tools 3-9
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
Unsupported
Processor Detected
System Halted.
1 long, 1 short Processor not supported by
current system ROM.
Check documentation for
supported processors. If
supported, remove the
processor and update system to
latest ROM.
101-ROM Error 1 long, 1 short System ROM checksum Run Compaq Diagnostics.
Replace failed assembly as
indicated.
101-I/O ROM Error None Options ROM checksum Run Compaq Diagnostics.
Replace failed assembly as
indicated.
102-System Board
Failure
None 8237 DMA controllers, 8254
timers, etc.
Replace the system board. Run
the server setup utility.
104-ASR-2 Timer
Failure
None System board failure Run Compaq Diagnostics.
Replace failed assembly as
indicated.
105-Current System
ROM is corrupt –
now booting
redundant System
ROM
2 long Non-booted ROM image is
corrupted
Flash the ROM using ROMPaq.
162-System Options
Not Set
2 short Configuration incorrect Run the server setup utility and
correct.
163-Time & Date Not
Set
2 short Invalid time or date in
configuration memory
Run the server setup utility and
correct.
164-Memory Size
Error
2 short Configuration memory incorrect Run the server setup utility and
correct.
172-Configuration
Non-volatile Memory
Invalid
None Nonvolatile configuration corrupt
or jumper installed
Run the server setup utility and
correct.
173-Slot ID
Mismatch
None Board replaced, configuration not
updated
Run the server setup utility and
correct.
174-Configuration/
Slot Mismatch Device
Not Found
None EISA or PCI board not found Run the server setup utility and
correct.
175-Configuration/
Slot Mismatch Device
Found
None EISA or PCI board added,
configuration not updated
Run the server setup utility and
correct.
177-Configuration
Not Complete
None Incomplete System Configuration
detected.
Run the server setup utility and
correct.
178-Processor
Configuration Invalid
None Processor type or step does not
match configuration memory.
Run the server setup utility and
correct.