DS10 / DS10L Console Reference
1-6
Figure 1–4 Physical Numbering for DS10 PCI Slots
64 Bit
64 Bit
64 Bit
32 Bit
PCI Slot 4
PCI Slot 3
PCI Slot 2
PCI Slot 1
PK1045-99
➊ Memory size is determined.
➋ The PCI bridges and attendant buses (indicated as IODn by the console)
are probed and the devices are reported. I/O adapters are configured.
➌
Power-up slot 14 corresponds to the bottom physical slot, slot 1.
Slot Location Physical Slot Number Logical Slot Number
Top 4 17
Second from top 3 16
Second from bottom 2 15
Bottom 1 14
➍ These devices are behind bridge of the card in logical slot 15, physical slot
2, second from the bottom.
➎
This device in is logical slot 16, physical slot 3.
➏ Logical slot 17 is physical slot 4, the top slot.
➐ The SRM console banner and prompt (>>>) are printed.
The SRM console is a command-line interface you use to set or read system
parameters.
If the auto_action environment variable is set to boot or restart and the
os_type environment variable is set to unix or openvms, the Tru64 UNIX
or OpenVMS operating system boots. See Section 2.18 for information on
environment variables.
Comments to this Manuals