Page view 97
2-46 DS10 / DS10L Console Reference
In firm bypass mode, you cannot enter RMC mode. To enter RMC mode
from firm bypass mode, reset the com1_mode variable from the SRM
console.
Syntax: set com1_mode value
where value can be:
snoop
soft_bypass
firm_bypass
Data partially bypasses RMC, but RMC taps into the data lines
and listens passively for the RMC escape sequence.
Data bypasses RMC, but RMC switches automatically into snoop
mode if an alert condition or loss of carrier occurs.
Data bypasses RMC. RMC is effectively disabled.
Example:
>>> set com1_mode
COM1_MODE (SNOOP, SOFT_BYPASS, FIRM_BYPASS)
2.18.6 console
The console terminal can be either a graphics monitor or a
serial terminal. The console environment variable specifies
which is used. Whenever you change the value of console, you
must reset the system by pressing the Halt/Reset button or
issuing the initialize command.
Syntax: set console output_device
where output_device can be:
graphics
(default)
The console terminal is a graphics monitor or a device connected
to the VGA or TGA module.
serial
The console terminal is the device connected to the COM1 port.